Storage Technical Info
Middle America Steel’s Commercial Self Storage
Standards:
Buy American Act Compliant
Code: IBC 2006 / Category II / Exposure C / Loads: 20# LL / 30# Snow / 100 MPH Wind /
8’6” eave height with 1/2:12 roof pitch.
Tek-screw together pre-engineered structures.
16 gauge 12” structural mullion between doors.
16 gauge and 14 gauge red-iron roof purlins and wall girts.
Red-iron base angle and galvanized base channels.
14 gauge galvanized stamped base clips with hole for ½” bolts.
½”x2 7/8” wedge anchor bolts.
26 gauge 20 year galvalume “PBR” roof panels
26 gauge silicone-polyester paint 40 year “PBR” wall panels.
29 gauge galvalume interior partition panels.
Long life roof fasteners.
Mastic sealant at all roof lap seams.
Guttering and downspouts.
Jamb and header cover trim on framed openings.
4070 & 9070 Janus roll-up-doors.
Full erection drawings.
Underwriters Laboratories Class 90 Wind Uplift Rating and UL Class 4 Impact Resistance Rating.
Optional Accessories
Standing seam roof panels.
Climate controlled building as well as hybrid buildings.
Design and unit mix layout and feasibility studies.
Engineer sealed erection drawings.
¼”reflective foil insulation.
3” & 4” fiberglass insulation with reinforced vinyl/reflective foil backing for climate control.
4070 steel walkdoors for climate control entry.
Custom roll-up-door sizes.
White liner panels for climate control halls.
Mezzanines for multi story storage.
1:12 – 5:12 roof pitches.
Fully insured Professional steel erection.